VN6/VN6SHFO/VN6HFO
VN8/VN8SHFO/VN8HFO
Neonatal and Pediatric Ventilator
See the Breath Shape the Outcome VN8HFO
Designed for neonates, premature infants, and pediatric patients with birth weight ≥200 g. Delivering full-cycle precision ventilation protection - from lung recruitment preparation through ventilator weaning assessment.
The VN8HFO is a comprehensive neonatal ventilator engineered for critical care environments. It covers every key clinical intervention from pre-intubation lung recruitment preparation through to post-stabilization weaning assessment, with 17 ventilation modes and 5 exclusive patents providing complete respiratory protection.
Core Clinical Benefits
Precise Volume Control
Stable Ventilation
Seamless Full-Cycle Care
Ultra-Quiet Operation
17 Ventilation Modes
The VN8HFO supports 17 ventilation modes covering the full spectrum of neonatal respiratory needs - from conventional pressure and volume control modes through high-frequency oscillation (HFO, PC-HFO) and non-invasive high-flow nasal cannula (HFNC) therapy.
5 Exclusive Patents — Full Neonatal Ventilation Protection
Five synergistic patents build a complete safety and precision framework — from oscillation mechanics to trigger synchronization and airway cuff management. Each patent targets a distinct clinical challenge in neonatal ventilation.
Revolutionary HFOV-VG Volume Guarantee
Industry-leading volume guarantee high frequency ventilation technology with tidal volume as low as 0.1mL, providing a ventilation safety net for the fragile lungs of neonates.
Patented Voice Coil
Patented diaphragm oscillation system with rolling motion + special weight component design, realizes higher frequency, smoother and quieter oscillation output, suitable for premature infants and infants with low lung compliance.
Four-fold Synchronous Trigger Technology
Provides four trigger modes of flow, volume, pressure and abdomen, accurately matches the infant's spontaneous breathing, optimizes synchronization timing, and greatly reduces patient-ventilator asynchrony.
IntelliCuff Intelligent Cuff Management Patent
Continuously monitors and automatically maintains stable ETT cuff pressure, reduces airway mucosal injury and the risk of ventilator-associated pneumonia.
TRC Tube Resistance Compensation Technology
Automatically compensates for the respiratory resistance caused by endotracheal intubation, reduces the infant's work of breathing, and improves ventilation comfort.
Revolutionary HFOV-VG Volume Guarantee
Industry-leading volume guarantee high frequency ventilation technology with tidal volume as low as 0.1mL, providing a ventilation safety net for the fragile lungs of neonates.
Patented Voice Coil
Patented diaphragm oscillation system with rolling motion + special weight component design, realizes higher frequency, smoother and quieter oscillation output, suitable for premature infants and infants with low lung compliance.
Core Patent Technology — diaphragm oscillation
VN8HFO adopts the most recognized method, diaphragm oscillation, and applied Comen’s unique and advance design which provide a quieter and more powerful oscillator, covering all the scenario in practice.
During ventilation, the system automatically compensates for unexpected circuit or mask leaks that compromise tidal volume delivery and trigger accuracy, with a maximum leak compensation flow of 45 L/min in pediatric mode.
Backup Ventilation — Safety System & Neonatal Sensor Backup
VN8HFO employs three intelligent triggers (Flow / Pressure / Abdominal) to seamlessly synchronize with spontaneous breathing, enabling precise identification of each respiratory phase and optimizing human-machine interaction for superior patient comfort.
Pressure Sensor
Applicable to Dual-limb NIV and Invasive Ventilation Modes
Flow Sensor
Abdominal Sensor
In non-invasive single-limb mode, a pressure generator is required.