COMEN Logo
COMEN VN8 Ventilateur

VN6/VN6SHFO/VN6HFO VN8/VN8SHFO/VN8HFO

Neonatal and Pediatric Ventilator

COMEN VN8 Ventilateur

VN6/VN6SHFO/VN6HFO VN8/VN8SHFO/VN8HFO

Neonatal and Pediatric Ventilator

See the Breath Shape the Outcome

Designed for neonates, premature infants, and pediatric patients with birth weight ≥200 g. Delivering full-cycle precision ventilation protection - from lung recruitment preparation through ventilator weaning assessment.

VN8HFO neonatal ventilation workflowVN8HFO pediatric ventilation interface

Integrated Ventilation - Full-Cycle Neonatal Solution

The VN8HFO is a comprehensive neonatal ventilator engineered for critical care environments. It covers every key clinical intervention from pre-intubation lung recruitment preparation through to post-stabilization weaning assessment, with 17 ventilation modes and 5 exclusive patents providing complete respiratory protection.

Core Clinical Benefits

Precise Volume Control

Precise Volume Control

Stable Ventilation

Stable Ventilation

Seamless Full-Cycle Care

Seamless Full-Cycle Care

Ultra-Quiet Operation

Ultra-Quiet Operation

17 Ventilation Modes

The VN8HFO supports 17 ventilation modes covering the full spectrum of neonatal respiratory needs - from conventional pressure and volume control modes through high-frequency oscillation (HFO, PC-HFO) and non-invasive high-flow nasal cannula (HFNC) therapy.

17 Ventilation Modes — complete neonatal and pediatric coverage

5 Exclusive Patents — Full Neonatal Ventilation Protection

Five synergistic patents build a complete safety and precision framework — from oscillation mechanics to trigger synchronization and airway cuff management. Each patent targets a distinct clinical challenge in neonatal ventilation.

Revolutionary HFOV-VG Volume Guarantee

Industry-leading volume guarantee high frequency ventilation technology with tidal volume as low as 0.1mL, providing a ventilation safety net for the fragile lungs of neonates.

Revolutionary HFOV-VG Volume Guarantee

Patented Voice Coil

Patented diaphragm oscillation system with rolling motion + special weight component design, realizes higher frequency, smoother and quieter oscillation output, suitable for premature infants and infants with low lung compliance.

Patented Voice Coil

Four-fold Synchronous Trigger Technology

Provides four trigger modes of flow, volume, pressure and abdomen, accurately matches the infant's spontaneous breathing, optimizes synchronization timing, and greatly reduces patient-ventilator asynchrony.

Four-fold Synchronous Trigger Technology

IntelliCuff Intelligent Cuff Management Patent

Continuously monitors and automatically maintains stable ETT cuff pressure, reduces airway mucosal injury and the risk of ventilator-associated pneumonia.

IntelliCuff Intelligent Cuff Management Patent

TRC Tube Resistance Compensation Technology

Automatically compensates for the respiratory resistance caused by endotracheal intubation, reduces the infant's work of breathing, and improves ventilation comfort.

TRC Tube Resistance Compensation Technology

Revolutionary HFOV-VG Volume Guarantee

Industry-leading volume guarantee high frequency ventilation technology with tidal volume as low as 0.1mL, providing a ventilation safety net for the fragile lungs of neonates.

Revolutionary HFOV-VG Volume Guarantee

Patented Voice Coil

Patented diaphragm oscillation system with rolling motion + special weight component design, realizes higher frequency, smoother and quieter oscillation output, suitable for premature infants and infants with low lung compliance.

Patented Voice Coil

HFOV Technology — diaphragm oscillation

VN8HFO adopts the most recognized method, diaphragm oscillation, and applied Comen's unique and advance design which provide a quieter and more powerful oscillator, covering all the scenario in practice.

  • HFO+ Volume Guarantee
  • Friction Reduction
  • Linear amplitude
  • Smooth sine wave
  • Patented noise reduction
HFOV Technology — diaphragm oscillation

PREPARATION

Pre-ventilation precision setup — ensuring accurate airway pressure delivery and lung recruitment

Lung Recruitment — Sustained Inflation (SI)*

Contraindications:Sputum suction, O₂ therapy, Spontaneous breathing without sedation.

Lung Recruitment — Sustained Inflation (SI)*

Facilitates reopening of collapsed alveoli and prevents secondary lung collapse from low tidal volume ventilation.

*Pediatric ONLY, not for neonatal use.

TRC — Tube Resistance Compensation

Before initiating invasive ventilation, configure tube resistance compensation to ensure accurate pressure delivery at patient's airway.

TRC — Tube Resistance Compensation

Ensures pressure at tube end matches ventilator settings, compensating for resistance in endotracheal/tracheostomy tubes.

Lung Recruitment — Sustained Inflation (SI)*

Contraindications:Sputum suction, O₂ therapy, Spontaneous breathing without sedation.

Lung Recruitment — Sustained Inflation (SI)*

Facilitates reopening of collapsed alveoli and prevents secondary lung collapse from low tidal volume ventilation.

*Pediatric ONLY, not for neonatal use.

TRC — Tube Resistance Compensation

Before initiating invasive ventilation, configure tube resistance compensation to ensure accurate pressure delivery at patient's airway.

TRC — Tube Resistance Compensation

Ensures pressure at tube end matches ventilator settings, compensating for resistance in endotracheal/tracheostomy tubes.

APPLICATION

Multi-dimensional safety protection and real-time adaptive circuit management during ventilation

Backup Ventilation — Safety System & Neonatal Sensor Backup

Apnea Ventilation Backup

Apnea Ventilation Backup

Neonatal Sensor Backup

Neonatal Sensor Backup

HFO Safety Protection — Multi-Level Pressure Monitoring

During high-frequency ventilation modes requiring continuous pressure monitoring and safety interventions.

HFO Safety Protection — Multi-Level Pressure Monitoring

Automatic Leakage Compensation — Real-time Circuit Management

During ventilation, the system automatically compensates for unexpected circuit or mask leaks that compromise tidal volume delivery and trigger accuracy, with a maximum leak compensation flow of 45 L/min in pediatric mode.

Automatic Leakage Compensation — Real-time Circuit Management

Backup Ventilation — Safety System & Neonatal Sensor Backup

Apnea Ventilation Backup

Apnea Ventilation Backup

Neonatal Sensor Backup

Neonatal Sensor Backup

HFO Safety Protection — Multi-Level Pressure Monitoring

During high-frequency ventilation modes requiring continuous pressure monitoring and safety interventions.

HFO Safety Protection — Multi-Level Pressure Monitoring

EVALUATION

Objective assessment of lung function recovery and ventilator weaning readiness

Weaning Tools & Spontaneous Breathing Trial (SBT)

Contraindications:When patient condition improves, assess readiness for ventilator weaning with objective parameter trends.

Mode : PSV O2 %, ΔPsupp, PEEP, minuteries de durée et d'endurance

Indicateur d'arrêt automatiqueIndicateur d'arrêt automatique
Weaning Tools & Spontaneous Breathing Trial (SBT)

FRC Measurement — Functional Residual Capacity Assessment

Enables assessment of pulmonary function recovery, lung recruitment effectiveness, and guides PEEP optimization.

After stabilization, assess lung function and ventilation strategy effectiveness through FRC measurement.

FRC Measurement — Functional Residual Capacity Assessment

Weaning Tools & Spontaneous Breathing Trial (SBT)

Contraindications:When patient condition improves, assess readiness for ventilator weaning with objective parameter trends.

Mode : PSV O2 %, ΔPsupp, PEEP, minuteries de durée et d'endurance

Indicateur d'arrêt automatiqueIndicateur d'arrêt automatique
Weaning Tools & Spontaneous Breathing Trial (SBT)

FRC Measurement — Functional Residual Capacity Assessment

Enables assessment of pulmonary function recovery, lung recruitment effectiveness, and guides PEEP optimization.

After stabilization, assess lung function and ventilation strategy effectiveness through FRC measurement.

FRC Measurement — Functional Residual Capacity Assessment

Tout COMEN, avec une considération globale

COMEN propose sa propre marque d'accessoires de ventilation, protégeant le flux de gaz à chaque étape. Une structure affinée avec des matériaux soigneusement sélectionnés augmente le confort et réduit l'espace mort ainsi que le travail respiratoire (WOB).

Circuit respiratoire

RN2-201H & RN2-101H*

RN2-201H & RN2-101H*

Circuit respiratoire néonatal chauffant jetable avec chambre d'humidification jetable Circuit respiratoire néonatal jetable (godet d'eau inclus) avec chambre d'humidification jetable

Circuit respiratoire
  • Adaptable en branche unique et double branche
  • Structure optimale avec moins d'espace mort

*Non marqué CE

Humidification

CM-V20-001 /CM-V21-001R*

CM-V20-001 /CM-V21-001R*

Chambre d'humidification néonatale réutilisable Chambre d'humidification néonatale jetable (alimentation automatique)

HT50/HT30

HT50/HT30

Humidificateur chauffant non invasif Humidificateur chauffant invasif

  • Moins de condensation
  • Détection sensible des faibles débits d'air
  • Utilisation facile

Capteurs intelligents pour une synchronisation douce

Capteur abdominal

Capteur abdominal

  • Détecte plus tôt l'effort respiratoire grâce au mouvement abdominal
  • Insensible aux fuites du circuit, à la condensation, aux fluctuations de pression, à la toux ou aux pleurs
  • Économique et efficace
Capteur de débit*

Capteur de débit*

  • Améliore la ventilation néonatale grâce à l'ADRC, à une détection de débit haute précision, à un espace mort minimal, à une réponse rapide et à une surveillance précise du volume courant jusqu'à 0,1 mL

*Non marqué CE

Interface patient

NV Flow*

NV Flow*

  • Générateur de débit avec canules nasales ou masques
  • Applicable pour nCPAP/(S)NIPPV/nHFO
  • Sensible pour la synchronisation
Canules nasales et masques*

Canules nasales et masques*

  • Assurent une étanchéité efficace et réduisent les fuites tout en aidant à prévenir les lésions nasales
  • Conception ergonomique et silicone souple pour un positionnement et un confort optimaux
Bonnet de fixation*

Bonnet de fixation*

  • Prévient les lésions nasales : la canule/le masque sont fixés par des sangles horizontales aux narines, réduisant la force de traction vers le haut sur le nez du nourrisson.
Neo.flow*

Neo.flow*

  • Canule souple, anatomiquement incurvée, pour réduire la résistance au flux d'air et avec une tendance à réduire les traumatismes nasaux

*Non marqué CE

Circuit respiratoire

RN2-201H & RN2-101H*

RN2-201H & RN2-101H*

Circuit respiratoire néonatal chauffant jetable avec chambre d'humidification jetable Circuit respiratoire néonatal jetable (godet d'eau inclus) avec chambre d'humidification jetable

Circuit respiratoire
  • Adaptable en branche unique et double branche
  • Structure optimale avec moins d'espace mort

*Non marqué CE

Humidification

CM-V20-001 /CM-V21-001R*

CM-V20-001 /CM-V21-001R*

Chambre d'humidification néonatale réutilisable Chambre d'humidification néonatale jetable (alimentation automatique)

HT50/HT30

HT50/HT30

Humidificateur chauffant non invasif Humidificateur chauffant invasif

  • Moins de condensation
  • Détection sensible des faibles débits d'air
  • Utilisation facile

Capteurs intelligents pour une synchronisation douce

Capteur abdominal

Capteur abdominal

  • Détecte plus tôt l'effort respiratoire grâce au mouvement abdominal
  • Insensible aux fuites du circuit, à la condensation, aux fluctuations de pression, à la toux ou aux pleurs
  • Économique et efficace
Capteur de débit*

Capteur de débit*

  • Améliore la ventilation néonatale grâce à l'ADRC, à une détection de débit haute précision, à un espace mort minimal, à une réponse rapide et à une surveillance précise du volume courant jusqu'à 0,1 mL

*Non marqué CE

COMEN Retour en haut
COMEN ContactCOMEN Contact