COMEN Logo
COMEN V3&V3Pro Ventilators

V3/V3 Pro

Ventilator

COMEN V3&V3Pro Ventilators

V3/V3 Pro

Ventilator

The V3 Pro is a powerful yet portable ICU ventilator, featuring turbine-driven technology, a hidden carry handle, and extended battery life for true mobility. It supports a full range of patients from neonates to adults, offers advanced ventilation modes, and comes equipped with comprehensive clinical support tools.

Impressive Ventilation Performance

With 18 ventilation modes and high flow oxygen therapy, V3 Pro provides full patient support throughout their treatment journey, from admission to discharge. Our ventilators can assist patients in various stages, from intubation to weaning, invasive to non-invasive ventilation, and even during high-flow oxygen therapy. Our V3 Pro ventilator will meet all your needs without switching between different devices during recovery.

COMEN V3&V3Pro VentilatorsCOMEN V3&V3Pro Ventilators
COMEN V3&V3Pro Ventilators

Improved Human-Machine Synchronization

Brand new iV-Cycle technology gives V3 Pro the ability to intelligently sense patient's demand for each breath and greatly improves man-machine synchronization in both inspiration and expiration.

Transcends Cinical Boundaries

Engineered for dynamic healthcare environments, V3Pro ventilator offers clinical adaptability through its all-in-one portability concept. Featuring an ultra-lightweight design, endurance-optimized power system, and one-button mobility solutions, it seamlessly serves ER interventions, ICU treatments, intra-hospital transfers, and routine care scenarios, ensuring uninterrupted respiratory support across care continuum.

COMEN V3&V3Pro VentilatorsCOMEN V3&V3Pro VentilatorsCOMEN V3&V3Pro Ventilators
COMEN V3&V3Pro Ventilators

Super Light Weight

V3 Pro’s weight is down to 10kg, easy to carry and operate

COMEN V3&V3Pro Ventilators

Longer Battery Life

V3 Pro’s battery supports up to 6.6h ventilation

COMEN V3&V3Pro Ventilators

Hidden Handle

Designed with a hidden handle that blends seamlessly into the body, this space-saving feature lets you grab and go whenever you need

COMEN V3&V3Pro Ventilators

Internal Turbine Charged

Integrated high-performance turbine provides pneumatic ventilation without air supply

COMEN V3&V3Pro Ventilators

Higher Mobility Trolley

V3 Pro can be mounted both on trolley or transportation bed

COMEN V3&V3Pro Ventilators

Super Light Weight

V3 Pro’s weight is down to 10kg, easy to carry and operate

COMEN V3&V3Pro Ventilators

Longer Battery Life

V3 Pro’s battery supports up to 6.6h ventilation

COMEN V3&V3Pro Ventilators

Hidden Handle

Designed with a hidden handle that blends seamlessly into the body, this space-saving feature lets you grab and go whenever you need

COMEN V3&V3Pro Ventilators

Internal Turbine Charged

Integrated high-performance turbine provides pneumatic ventilation without air supply

COMEN V3&V3Pro Ventilators

Higher Mobility Trolley

V3 Pro can be mounted both on trolley or transportation bed

COMEN V3&V3Pro Ventilators

Super Light Weight

V3 Pro’s weight is down to 10kg, easy to carry and operate

COMEN V3&V3Pro Ventilators

Longer Battery Life

V3 Pro’s battery supports up to 6.6h ventilation

COMEN V3&V3Pro Ventilators

Hidden Handle

Designed with a hidden handle that blends seamlessly into the body, this space-saving feature lets you grab and go whenever you need

COMEN V3&V3Pro Ventilators

Internal Turbine Charged

Integrated high-performance turbine provides pneumatic ventilation without air supply

COMEN V3&V3Pro Ventilators

Higher Mobility Trolley

V3 Pro can be mounted both on trolley or transportation bed

Lung Protection Ventilation Strategy

As our understanding of mechanical ventilation and its potential for lung injury evolves, new concepts have emerged over time. From "volumetrauma" and "barotrauma" first introduced in 1985, to the "low tidal volume ventilation" strategy in the early 21st century, and more recently, "stress and strain," our comprehension of protective ventilation continues to develop. In response to these advancements, Comen is constantly optimizing our functionalities to reduce the burden on healthcare professionals while ensuring patient safety.

Comprehensive Assessment of Ventilator-Related Factors Impacting Lung Injury

To understand the multifaceted influences of mechanical ventilation on lung injury, it is critical to monitor:

Mechanical Power Monitoring

V3 Pro monitors real-time mechanical power, guiding the individualized mechanical strategy.

Driving Pressure Monitoring

Driving pressure (ΔP) predicts ventilator-induced lung injury risk, guiding tidal volume/PEEP optimization to reduce alveolar overdistension in ARDS.

COMEN V3&V3Pro Ventilators

Low Tidal Volume Ventilation

Low tidal volume ventilation is at the core of current lung-protective ventilation strategies. The recommended tidal volume typically ranges from 6-8 ml/kg (based on ideal body weight) to minimize VILI.

Tidal Volume Recommendation

To adjust tidal volume based on ideal body weight.

COMEN V3&V3Pro Ventilators

C20/C

To provide monitoring to assess lung expansion and prevent excessive tidal volumes.

COMEN V3&V3Pro Ventilators

Personalized PEEP Titration

Appropriate (PEEP) helps maintain alveolar patency and prevents atelectasis. The selection of PEEP should be tailored to each patient’s individual condition, achieving optimal gas exchange while minimizing lung injury.

Static P-V loop

Utilize a pressure-volume tool for individualized assessment.

COMEN V3&V3Pro Ventilators

Stress Index

To further evaluate the compliance of respiratory system.

COMEN V3&V3Pro Ventilators

Recruitment Maneuver

Recruitment strategies intermittently increase airway pressures to reopen collapsed alveoli that have suffered from inadequate ventilation.

Sigh

To use sigh maneuvers to facilitate recruitment.

COMEN V3&V3Pro Ventilators

Sustained Inflation

To employ sustained inflation techniques for effective recruitment.

COMEN V3&V3Pro Ventilators

Comprehensive Assessment of Ventilator-Related Factors Impacting Lung Injury

To understand the multifaceted influences of mechanical ventilation on lung injury, it is critical to monitor:

Mechanical Power Monitoring

V3 Pro monitors real-time mechanical power, guiding the individualized mechanical strategy.

Driving Pressure Monitoring

Driving pressure (ΔP) predicts ventilator-induced lung injury risk, guiding tidal volume/PEEP optimization to reduce alveolar overdistension in ARDS.

COMEN V3&V3Pro Ventilators

Low Tidal Volume Ventilation

Low tidal volume ventilation is at the core of current lung-protective ventilation strategies. The recommended tidal volume typically ranges from 6-8 ml/kg (based on ideal body weight) to minimize VILI.

Tidal Volume Recommendation

To adjust tidal volume based on ideal body weight.

COMEN V3&V3Pro Ventilators

C20/C

To provide monitoring to assess lung expansion and prevent excessive tidal volumes.

COMEN V3&V3Pro Ventilators

From Experience-Driven to Data-Powered

Reliable Weaning Tool

RSBI

Rapid Shallow Breathing Index

SBT

Spontaneous Breathing Trial

NIF

Negative Inspiratory Force

P0.1

Airway occlusion pressure at 0.1 second

An SBT is a clinical procedure used to assess a patient's ability to breathe spontaneously and independently without the support of mechanical ventilation. It is a crucial step in the process of weaning a patient from the ventilator.

Innovative HFNC Evaluation Tool

Collecting data from high-flow oxygen therapy patients for accurately assessing the prognosis status of ARDS. When there is no arterial blood gas analysis, the oxygenation index will assist in the prediction and prognosis judgment of respiratory diseases.

COMEN V3&V3Pro Ventilators

Precision Calculation

Energy Metabolism Calculation

It enables personalized nutrition plans, preventing under-/over-nutrition support while enhancing recovery.

COMEN V3&V3Pro Ventilators
Alveolar Ventilation Calculation

By measuring alveolar dead space, tidal volume, and oxygenation index, it helps clinicians evaluate effective ventilation.

COMEN V3&V3Pro Ventilators

Hassle-Free Maintenance

COMEN V3&V3Pro Ventilators

Tired of These Maintenance Headaches?

Stressing about cross-infection after every use?
Chasing consumables that never last?
Drowning in calibration logs every month?
Nervous about turbo maintenance?
COMEN V3&V3Pro Ventilators
COMEN V3&V3Pro Ventilators

Relax! V3pro Has Your Back.

20,000 Hours of “Set It & Forget It”

Modular turbo cartridge: One-click removal, no tools needed.2.3 years (20,000 hours) of continuous runtimeSmart alerts: Proactive notifications for turbine servicing

COMEN V3&V3Pro Ventilators

High-performance turbine

Infection Control, Simplified in Seconds

Autoclave it or soak it: High-temp sterilization and chemical disinfection kill hidden biofilms. Every breath starts 100% clean.No tools, no fuss: Two-step snap-off design. Swap valves solo in 5 seconds flat.

COMEN V3&V3Pro Ventilators

Dual valves for inhalation and exhalation

Consumables? More Like “Can’t-Bother-ables”

Zero Calibration, Zero Replacements: Lifetime use without recalibration or consumable purchases.Factory-Calibrated Precision: Ready for accurate operation upon startup—no annual calibration required.5+ Years of Durability: Engineered for relentless performance

COMEN V3&V3Pro Ventilators

Non-comsumable ultrasonic oxygen sensor

20,000 Hours of “Set It & Forget It”

Modular turbo cartridge: One-click removal, no tools needed.2.3 years (20,000 hours) of continuous runtimeSmart alerts: Proactive notifications for turbine servicing

COMEN V3&V3Pro Ventilators

High-performance turbine

Infection Control, Simplified in Seconds

Autoclave it or soak it: High-temp sterilization and chemical disinfection kill hidden biofilms. Every breath starts 100% clean.No tools, no fuss: Two-step snap-off design. Swap valves solo in 5 seconds flat.

COMEN V3&V3Pro Ventilators

Dual valves for inhalation and exhalation

COMEN Back to Top
Contact UsContact Us