Dependable and Productive Solution for Confident Diagnosis
Technical support
Pre-sales consultation
Dependable and Productive Solution for Confident Diagnosis
Compact model of 3-diff hematology analyzers adopts cyanide free method, colorimetry method together with multiple histigrams prevent error analysis testing, fast testing speed typically suitable for laboratories with busy workflow, and requirement of less manual operation and long-term stability.
Achieve a real throughput of 60 tests per hour, significantly streamlining your blood counting procedures.
Utilize a sensitive flag detector to support informed diagnostic decision-making.
Benefit from clogging removal and an automated cooling and heating system for smoother operations.
{{ p }}
Applicable to various patient blood type including infant,pediatric,babies. Moreover, only 11.5 microlitre of blood is required under CBC mode to deliver an accurate testing results, particularly suit to patient with difficulty in blood collection.
WBC
RBC
PLT
3 blood reagent is need , consuming 70% less reagent compared to other analyzers available in the market with a complete set of original reagents, exquisite internal modules design ensure extremely convenient for installatio
Support open and close system to meet various end user demands
{{ p }}
The latex-enhanced immune nephelometry method enables comprehensive testing of complete blood count (CBC), routine CRP, and high-sensitivity CRP. CRP is automatically calibrated based on the level of red blood cell aggregation in the sample, eliminating the influence of blood cell volume. This ensures that the testing results of whole blood samples are consistent with serum samples.
Add Lyse
Reagent
Sample to
be Tested
Add Latex
Reagent
Immune
Response
Nephelometry
Detection
Principles
Impedance method for WBC, RBC and PLT counting
Colorimetry method for hemoglobin test
Parameters
24 reportable parameters: WBC, Lym#, Lym%, Mid#, Mid%, Gran#,
Gran%, RBC, HGB, MCV, MCH, MCHC, RDW-CV, RDW-SD, HCT, PLT,
MPV, PDW, PCT, P-LCR, P-LCC, FR-CRP,hs-CRP,CRP
3 histograms for WBC, RBC and PLT
2 research parameters: NLR, PLR
Sample Volume
Whole blood mode ≤ 9
Pre-diluted mode ≤ 20
Throughput
60 samples per hour
Display
10.4 inch-touch screen
Data storage capacity
Up to 200000
Communication
Support LIS and external printer
Interface
4 USB (supports USB 2.0 protocol)
Bi-directional LIS through LAN port (HL7 protocol)
Environmental requirement
Temperature: 10℃~35℃
Humidity: 20%~90%
Air pressure: 70kp-106kp
Power requirement
AC input voltage: 100-240V
AC input frequency: 50Hz/60Hz
Maximum power consumption: 240VA
Dimensions
281mm (W) × 412mm(H) × 490mm (D)
Weight
≤25kg
Performance